Fri Jul 12 12:51:13 2013, Charles, Update, ISS, RMS Noise from PMC Transmission
|
Fri Jul 12 13:15:43 2013, Koji, Update, ISS, RMS Noise from PMC Transmission
|
Fri Jul 12 18:30:20 2013, Charles, Update, ISS, RMS Noise from PMC Transmission
|
|
Message ID: 8838
Entry time: Fri Jul 12 13:15:43 2013
In reply to: 8836
Reply to this: 8839
|
Author: |
Koji |
Type: |
Update |
Category: |
ISS |
Subject: |
RMS Noise from PMC Transmission |
|
|
It would be better to measure the power spectrum density of the fluctuation.
The RMS does not tell enough information how the servo should be.
In deed, the power spctrum density gives you how much the RMS is in the entire or a specific frequency range. |