Entry  Mon Jun 17 16:34:15 2013, Jenne, Update, LSC, Sensing Matrix vs. Schnupp Asymmetry 10x
    Reply  Mon Jun 17 21:10:25 2013, Jenne, Update, LSC, Sensing Matrix vs. Schnupp Asymmetry SchnuppLoop_PRMI_REFLdiodes.pngSchnuppLoop_DRMI_REFLdiodes.pngSchnuppLoop_PRFPMI_REFLdiodes.pngSchnuppLoop_DRFPMI_REFLdiodes.png
       Reply  Tue Jun 18 07:22:20 2013, Koji, Update, LSC, Sensing Matrix vs. Schnupp Asymmetry 
Message ID: 8711     Entry time: Mon Jun 17 16:34:15 2013     Reply to this: 8713
Author: Jenne 
Type: Update 
Category: LSC 
Subject: Sensing Matrix vs. Schnupp Asymmetry 

I have made some plots of the sensing matrix (PRCL / MICH amplitude ratio, and relative angle) versus Schnupp asymmetry for all the configurations that involve the power recycling cavity.  I am still meditating on what they mean for us, in terms of whether or not we should be changing our Schnupp asymmetry.

The Schnupp asymmetry scan starts at 1mm, rather than 0.  Also, recall that our current Schnupp asymmetry is 3.9cm.

PRMI:

SchnuppLoop_PRMI_REFLdiodes_zoom.png

SchnuppLoop_PRMI_REFLdiodes_phase.png

DRMI:

SchnuppLoop_DRMI_REFLdiodes_zoom.png

SchnuppLoop_DRMI_REFLdiodes_phase.png

PRFPMI:

SchnuppLoop_PRFPMI_REFLdiodes.png

SchnuppLoop_PRFPMI_REFLdiodes_zoom.png

SchnuppLoop_PRFPMI_REFLdiodes_phase.png

DRFPMI:

SchnuppLoop_DRFPMI_REFLdiodes.png

SchnuppLoop_DRFPMI_REFLdiodes_zoom.png

SchnuppLoop_DRFPMI_REFLdiodes_phase.png

ELOG V3.1.3-