Message ID: 8708     Entry time: Fri Jun 14 07:06:19 2013     In reply to: 8703
Author: Koji 
Type: Summary 
Category: Green Locking 
Subject: X arm ALS 

It's nice that we are now able to scan the cavity again. We got close to PRMI+one arm one step further.
The calibration of the scan frequency and the evaluation of the in-loop/out-of-loop error signal in terms of (Hz/rtHz) would be necessary.

The beat amplitude looks actually huge aIthough I don't know where you are monitoring.
Talk to Jamie to figure out how much the signal should be at the monitoring point.
If it is more than we are supposed to have, put an attenuator somewhere.