40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu May 23 20:39:50 2013, Jenne, Update, LSC, PRMI sensing matrix measured at 580.1Hz SensMat_23May2013.png
    Reply  Thu May 23 22:13:12 2013, Koji, Update, LSC, PRMI sensing matrix measured at 580.1Hz 
       Reply  Fri May 24 13:41:19 2013, Jenne, Update, LSC, PRMI sensing matrix measured at 580.1Hz SensMat_23May2013_withIQ.png
          Reply  Fri May 24 14:01:59 2013, Koji, Update, LSC, PRMI sensing matrix measured at 580.1Hz 
             Reply  Fri May 24 14:40:22 2013, Jenne, Update, LSC, PRMI sensing matrix: now what? 
                Reply  Fri May 24 22:18:33 2013, Jenne, Update, LSC, PRMI sensing matrix: Got it! SensMat_23May2013_withIQ_andCorrectPhases.png
                   Reply  Tue May 28 14:52:56 2013, Jenne, Update, LSC, PRMI sensing matrix: Got it! SensMat_21May2013_withIQ_andCorrectPhases.png
                      Reply  Tue May 28 17:06:04 2013, Koji, Update, LSC, PRMI sensing matrix: Got it! 
Message ID: 8641     Entry time: Fri May 24 14:01:59 2013     In reply to: 8640     Reply to this: 8642
Author: Koji 
Type: Update 
Category: LSC 
Subject: PRMI sensing matrix measured at 580.1Hz 

It's hard to believe but is AS55Q really almost insensitive to MICH?

Well, anyway, now it is the time to use the automatic demod phase (and input matrix) adjustment.

ELOG V3.1.3-