40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Tue May 14 01:56:20 2013, Jenne, Update, Green Locking, Xend Green tweaked
|
Tue May 14 02:19:13 2013, Koji, Update, Green Locking, Xend Green tweaked
|
Tue May 21 18:18:23 2013, Manasa, Update, Green Locking, Xend Green aligned
|
Tue May 21 23:29:57 2013, Manasa, Update, Green Locking, Xend Green aligned
|
Tue May 28 19:35:17 2013, Manasa, Update, Green Locking, Still searching for the X green beat note
|
Thu May 30 01:02:41 2013, Manasa, Update, Green Locking, Found it! 
|
Mon Jun 3 21:09:55 2013, Manasa, Update, Green Locking, X green beatnote through beatbox
|
Tue Jun 11 22:16:56 2013, Manasa, Summary, Green Locking, ALS for X arm
|
Thu Jun 13 22:31:12 2013, Manasa, Summary, Green Locking, X arm ALS 
|
Fri Jun 14 07:06:19 2013, Koji, Summary, Green Locking, X arm ALS
|
|
Message ID: 8610
Entry time: Tue May 21 23:29:57 2013
In reply to: 8607
Reply to this: 8651
|
Author: |
Manasa |
Type: |
Update |
Category: |
Green Locking |
Subject: |
Xend Green aligned |
|
|
X-green and PSL green have been aligned so that they interfere at the beat PD for X.
I haven't scanned the X-end NPRO temperature to find the beat note. I found the earlier elog when this was done (elog 6851) and will use those temperatures to start with. |