Subject: netGPIB stuff update/modernized/cleanedup/improved 

I did a bunch of cleanup work on the netGPIB stuff:

  • Removed extensions from all executable scripts (executables should not have language extensions)
  • fixed execution permissions on executables and modules
  • committed HP8590.py and HP3563A.py instrument modules, which were there but not included in the svn
  • committed NWAG4395A (was AG4395A_Run.py) to svn, and removed old "custom" copies (bad people!)
  • cleaned up, modernized, and fixed the netgpibdata program
  • removed plotting from netgpibdata, since it was only available for one instrument, there's already a separate program to handle it, and it's just plotting the saved data anyway
  • added a netgpibcmd program for sending basic commands to instruments.
  • added a README

Probably the most noticeable change is removing the extensions from the executables.   There seems to be this bad habit around here of adding extensions to executables.  It doesn't matter to the person running the program what language it was written in, so don't add extensions.  It only matters for libraries.