Message ID: 8607
Entry time: Tue May 21 18:18:23 2013
In reply to: 8569
Reply to this: 8610
|
Author: |
Manasa |
Type: |
Update |
Category: |
Green Locking |
Subject: |
Xend Green aligned |
|
|
X arm aligned to green.
Aligned the X arm to IR.
Used steering mirrors to align the X end green to the X arm while remaining locked for IR. X arm locks to green stably with GTRX at the PSL table measuring 235uW and corresponds to 2560counts in C!:ALS-TRX_OUT.
Next
1. PSL green alignment.
2. Search for beat note.
3. Resurrect ALS for X arm. |