Entry  Tue May 14 20:27:19 2013, Koji, Configuration, LSC, Openloop gain for PRMI lock May 13 LSCPRCLOLTF.pngLSCMICHOLTF.png130513.zip
    Reply  Wed May 15 00:45:28 2013, rana, Configuration, LSC, Openloop gain for PRMI lock May 13 
Message ID: 8577     Entry time: Wed May 15 00:45:28 2013     In reply to: 8574
Author: rana 
Type: Configuration 
Category: LSC 
Subject: Openloop gain for PRMI lock May 13 

 

 Pfft. Why 500 usec delay? We should be using the known parameters for the hardware and software AA/AI.