Entry  Mon Apr 1 16:16:16 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 
    Reply  Mon Apr 1 16:35:42 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 
    Reply  Tue Apr 2 21:11:42 2013, Rana, Update, optical tables, Optical Table Toolboxes Update 
       Reply  Wed Apr 3 19:01:06 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 
          Reply  Wed Apr 3 23:22:20 2013, rana, Update, optical tables, Optical Table Toolboxes Update 
             Reply  Thu Apr 11 16:29:23 2013, Albert, Update, optical tables, Optical Table Toolboxes Update Diagram.png
                Reply  Mon Apr 15 17:44:28 2013, Albert, Update, optical tables, Optical Table Toolboxes Update photo.JPG
                   Reply  Mon Apr 29 08:17:40 2013, Albert, Update, optical tables, Optical Table Toolboxes Update 
                      Reply  Mon Apr 29 08:22:57 2013, Steve, Update, SAFETY, safety training 
                         Reply  Mon Apr 29 15:53:49 2013, Albert, Update, optical tables, Optical Table Boxes 7x
Message ID: 8445     Entry time: Thu Apr 11 16:29:23 2013     In reply to: 8410     Reply to this: 8457
Author: Albert 
Type: Update 
Category: optical tables 
Subject: Optical Table Toolboxes Update 

Quote:

 There are some tips for how to appy nail polish on YouTube from MKNails and MissJenFABULOUS. Their tips on how to prepare the site for a strong bonding strength are probably helpful for our gold/nickel coated tools. For chrome tools we may need to abrade the surface with a stone or fine sandpaper for it to take the layer better. IF the YouTube videos don't do it for you, then I suggest contacting Tom Evans at LLO to find out what kind of nail polish he uses.

 This is the tentative box placement per optical table. The toolboxes are going to be color-coded by a combination of two colors (the order won't matter). The side of each toolbox will have a little panel to let you know which box corresponds to which set of colors.

On the diagram, the set of colors is simply the color of the box border and the color of the text.

If anyone has a problem with any of the colors or the box placement let me know before they are installed and become an annoyance:

Diagram.png

Box Placements:

ETMY: Box will be attached to the underside of the table by magnets. The box will be on the north side of the optical table.

POY: Box will be attached to the side of the optical table by magnets. The box will be on the west side of the optical table.

BSPRM: Box will be attached to the side of the optical table by magnets. The box will be on the west side of the optical table.

AS: Box will be attached to the side of the optical table by magnets. The box will be on the north side of the optical table.

PSL1: Box will be inside the optical table, in the northeast corner.

PSL2: Box will be inside the optical table, in the southwest corner.

POX: Box will be attached to the side of the optical table by magnets. The box will be on the south side of the optical table.

MC2: Box will be attached to the side of the optical table by magnets. The box will be on the south side of the optical table.

ETMX: Box will be attached to the side of the optical table by magnets. The box will be on the east side of the optical table.