40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 841     Entry time: Fri Aug 15 16:45:43 2008
Author: Sharon 
Type: Update 
Category:  
Subject: Converting from FIR to IIR 
I have been looking into different techniques to convert from FIR to IIR. This is so we can see how effective the adaptive FIR filter is in comparison to an IIR one with fewer taps.
For now I tried 2 matlab functions: Prony and stmcb (which works on LMS method).
I used the FIR wiener code, MC1_X, (c1wino) and applied the FIR to IIR algorithm.
Seems like the stmcb one works a bit better, and that there isn't much effect for having 1000 and not 400 taps.

Will keep updating on more results I have, and hopefully have the MC in time to actually check this live.
Attachment 1: fir2iir50.png  617 kB  | Show | Show all
Attachment 2: fir2iir400.png  588 kB  | Show | Show all
Attachment 3: fir2iir1000.png  605 kB  | Show | Show all
ELOG V3.1.3-