40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Mar 28 10:44:30 2013, Manasa, Update, Computers, c1lsc down cds_FE.pngcds_fe1.png
    Reply  Thu Mar 28 12:50:52 2013, Jenne, Update, Computers, c1lsc is fine 
Message ID: 8367     Entry time: Thu Mar 28 12:50:52 2013     In reply to: 8366
Author: Jenne 
Type: Update 
Category: Computers 
Subject: c1lsc is fine 

 Manasa told me that she did things in a different order than her old elog. 

She had

(1) ssh'ed to c1lsc and did a remote shutdown / restart,

(2) restarted fb,

(3) restarted the mxstream on c1lsc,

(4) restarted each model individually in some order that I forgot to ask.

However, with the situation as in her "before" screenshot, all that needed to be done was restart the mxstream process on c1lsc. 

Anyhow, when I looked at the OAF model, it was complaining of "no sync", so I restarted the model, and it came back up fine.  All is well again.