Manasa told me that she did things in a different order than her old elog.
She had
(1) ssh'ed to c1lsc and did a remote shutdown / restart,
(2) restarted fb,
(3) restarted the mxstream on c1lsc,
(4) restarted each model individually in some order that I forgot to ask.
However, with the situation as in her "before" screenshot, all that needed to be done was restart the mxstream process on c1lsc.
Anyhow, when I looked at the OAF model, it was complaining of "no sync", so I restarted the model, and it came back up fine. All is well again. |