Entry  Wed Mar 6 21:58:39 2013, Jenne, Update, Electronics, POX whitening was fine all along 
    Reply  Wed Mar 6 22:11:19 2013, Koji, Update, Electronics, POX whitening was fine all along 
       Reply  Thu Mar 7 18:41:03 2013, Jenne, Update, Electronics, POX whitening was fine all along POX11I.pngPOX11Q.png
    Reply  Thu Mar 7 11:43:15 2013, Jenne, Update, Electronics, POX and POY whitening DC gain left low 
Message ID: 8253     Entry time: Thu Mar 7 18:41:03 2013     In reply to: 8247
Author: Jenne 
Type: Update 
Category: Electronics 
Subject: POX whitening was fine all along 

Here are the transfer functions that we took back in 2011 (see elog 4915 and replies) for POX:

POX11I.png

POX11Q.png

The table of all whitening filter zpk values is on the wiki: https://wiki-40m.ligo.caltech.edu/Electronics/WhiteningFilters