Entry  Wed Mar 6 21:58:39 2013, Jenne, Update, Electronics, POX whitening was fine all along 
    Reply  Wed Mar 6 22:11:19 2013, Koji, Update, Electronics, POX whitening was fine all along 
       Reply  Thu Mar 7 18:41:03 2013, Jenne, Update, Electronics, POX whitening was fine all along POX11I.pngPOX11Q.png
    Reply  Thu Mar 7 11:43:15 2013, Jenne, Update, Electronics, POX and POY whitening DC gain left low 
Message ID: 8247     Entry time: Wed Mar 6 22:11:19 2013     In reply to: 8246     Reply to this: 8253
Author: Koji 
Type: Update 
Category: Electronics 
Subject: POX whitening was fine all along 

At the time you, den and I worked together, we could not lock the X-arm on TEM00 with the FM1s of the POX11 on.
We could lock the arm only on the higher order mode but he gain was low. Once we turned off the FM1s, we immediately
locked the cavity on TEM00.

Don't you have the direct measurement of the TF with FM1 on and off?