Thu Feb 28 02:43:49 2013, yuta, Update, LSC, some qualitative evidence of PRMI sideband lock
|
Thu Feb 28 03:25:27 2013, yuta, Update, LSC, PR gain ~ 25 from PRMI carrier lock
|
Thu Feb 28 03:41:31 2013, Koji, Update, LSC, PR gain ~ 25 from PRMI carrier lock
|
Sat Mar 2 05:53:15 2013, yuta, Update, LSC, stable lock of PRMI  
|
Sat Mar 2 14:52:02 2013, rana, Update, LSC, stable lock of PRMI
|
Sun Mar 3 22:16:46 2013, Jenne, Update, LSC, LSC whitening triggering started
|
Mon Mar 4 09:55:33 2013, rana, Update, LSC, LSC whitening triggering started
|
Tue Mar 5 18:36:27 2013, Jenne, Update, LSC, LSC whitening triggering started
|
|
Message ID: 8198
Entry time: Thu Feb 28 03:41:31 2013
In reply to: 8197
|
Author: |
Koji |
Type: |
Update |
Category: |
LSC |
Subject: |
PR gain ~ 25 from PRMI carrier lock |
|
|
VERY GOOD!
This is how the carrier lock PRMI should look like.
- There is more room to improve the differential ITM alignment to make the dark port more dark, then you will gain more PRG
- The AS spot is definitely clipped. |