Entry  Fri Feb 8 18:23:32 2013, Jamie, Summary, General, arbcav of half PRC with flipped PR2 prm23t-modes.pdfprm23t-geometry.pdf
    Reply  Fri Feb 8 19:29:44 2013, yuta, Summary, General, arbcav of half PRC with flipped PR2 
       Reply  Mon Feb 11 17:17:30 2013, Jamie, Summary, General, more analysis of half PRC with flipped PR2 foo.pdf
          Reply  Tue Feb 12 18:25:43 2013, Jamie, Summary, General, half PRC with astigmatic PR2/3 
Message ID: 8040     Entry time: Fri Feb 8 18:23:32 2013     Reply to this: 8041
Author: Jamie 
Type: Summary 
Category: General 
Subject: arbcav of half PRC with flipped PR2 

Arbcav with half PRC (flat temporary mirror in front of BS), PR2 RoC = 600m, PR3 RoC = -600m:

prm23t-modes.pdfprm23t-geometry.pdf

NOTE: this does NOT include the affect of the PR2 substrate in the cavity.  Arbcav does not handle that.  It would have to be modified to accept arbitrary ABCD matrices.

NOTE: I added to the mode plot the frequency separation of the first HOMs from the carrier (\omega_{10/01}), in units of carrier FSR.