40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Feb 6 11:59:12 2013, Jenne, Update, Locking, PRC cavity gains 
    Reply  Wed Feb 6 18:39:08 2013, Jenne, Update, Locking, PRC cavity gains 
       Reply  Wed Feb 6 19:59:35 2013, rana, Update, Locking, PRC cavity gains 
          Reply  Wed Feb 6 20:03:50 2013, Manasa, Update, Locking, PRC cavity gains 
       Reply  Wed Feb 13 14:21:19 2013, Jenne, Update, Locking, PRC cavity gains 
Message ID: 8017     Entry time: Wed Feb 6 20:03:50 2013     In reply to: 8015
Author: Manasa 
Type: Update 
Category: Locking 
Subject: PRC cavity gains 

Quote:

  Getting closer, but need to use the real measured AR reflectivity values, not the 1500 ppm guess. These should be measured at the correct angles and pol, using an NPRO.

 I'm still on that!

ELOG V3.1.3-