40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sun Feb 3 13:20:02 2013, Koji, Summary, General, Hypothesis mode_density_PRC.pdfmode_density_PRC.zip
    Reply  Mon Feb 4 10:45:51 2013, Jamie, Summary, General, rough analysis of aligned PRM-PR2 mode scan scan-labeled.pdf
       Reply  Mon Feb 4 11:10:59 2013, Koji, Summary, General, rough analysis of aligned PRM-PR2 mode scan 
          Reply  Mon Feb 4 19:33:19 2013, yuta, Summary, General, rough analysis of aligned PRM-PR2 mode scan 3peakdata.png
             Reply  Tue Feb 5 02:04:44 2013, yuta, Summary, General, rough analysis of aligned PRM-PR2 mode scan PRMPR2scan.png
                Reply  Tue Feb 5 03:16:51 2013, Koji, Summary, General, rough analysis of aligned PRM-PR2 mode scan 
                   Reply  Tue Feb 5 10:09:08 2013, yuta, Summary, General, rough analysis of aligned PRM-PR2 mode scan 
                      Reply  Tue Feb 5 11:30:19 2013, Koji, Summary, General, rough analysis of aligned PRM-PR2 mode scan 
                         Reply  Wed Feb 13 01:26:08 2013, yuta, Summary, General, rough analysis of aligned PRM-PR2 mode scan unbiased.png
       Reply  Wed Feb 6 15:20:55 2013, yuta, Summary, General, FWHM was wrong 
    Reply  Mon Feb 4 15:06:56 2013, Koji, Summary, General, Hypothesis 
    Reply  Mon Feb 4 19:48:32 2013, Jamie, Summary, General, arbcav recalc of PRC with correct ITM transmission mode_density_PRC_2.pdfmode_density_PRC_3.pdf
Message ID: 8002     Entry time: Tue Feb 5 11:30:19 2013     In reply to: 8000     Reply to this: 8074
Author: Koji 
Type: Summary 
Category: General 
Subject: rough analysis of aligned PRM-PR2 mode scan 

Makes sense. I mixed up n and n-1

Probability function: X = (x1 + x2 + ... + xn)/n, where xi = xavg +/- dx

Xavg = xavg*n/n = xavg

dXavg^2 = n*dx^2/n^2
=> dXavg = dx/sqrt(n)

Xavg +/- dXavg = xavg +/- dx/sqrt(n)