40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Jan 16 18:08:06 2013, Jenne, Update, Locking, Expected PRC gains
|
Wed Jan 16 20:27:16 2013, rana, Update, Locking, Expected PRC gains
|
Thu Jan 17 00:17:31 2013, Jenne, Update, Locking, Expected PRC gains
|
Wed Jan 23 18:16:11 2013, Manasa, Update, General, Laseroptik mirror - SN6
|
Wed Jan 23 20:24:05 2013, Koji, Update, General, Laseroptik mirror - SN6
|
Wed Jan 23 22:02:25 2013, Manasa, Update, General, Laseroptik mirror - SN6
|
Thu Jan 24 15:16:50 2013, Manasa, Update, General, Laseroptik mirror - SN6
|
Thu Jan 24 16:23:24 2013, Koji, Update, General, Laseroptik mirror - SN6
|
Tue Jan 29 14:20:02 2013, Koji, Update, General, Finer rotation stage for optics characterization
|
Thu Jan 24 16:34:56 2013, rana, Update, General, Laseroptik mirror - SN6
|
Fri Jan 25 08:10:42 2013, Steve, Update, General, Laseroptik mirrors
|
Mon Jan 28 19:07:45 2013, Manasa, Update, General, SN6 Laseroptik mirror - Tranmittance measurements 
|
|
Message ID: 7940
Entry time: Thu Jan 24 15:16:50 2013
In reply to: 7935
Reply to this: 7941
7943
7944
|
Author: |
Manasa |
Type: |
Update |
Category: |
General |
Subject: |
Laseroptik mirror - SN6 |
|
|
I repeated the transmittance measurements of Laseroptik SN6 at 1064nm. The rotation stage could only resolve 2 deg rotation (We should consider buying a better rotation stage).
s-polarization
Percentage transmittance
0.177% 42 deg
0.806% 44 deg
0.57% 46 deg
54.8% 0 deg
p-polarization
Percentage transmittance
1.039% 42deg
1.155% 44 deg
1.159% 46 deg
65.6% 0 deg
|