Message ID: 7832     Entry time: Fri Dec 14 09:31:59 2012     In reply to: 7829     Reply to this: 7833
Author: rana 
Type: Update 
Category: LSC 
Subject: High frequency noise in AS signal 

This is NOT calibrated. Its sort of calibrated in the 500-1000 Hz area, but does not correctly use the loop TF or the cavity pole.

As for the noise, remember that the whole point of changing the AS whitening gain was to turn on the whitening filter AFTER locking. With the WF OFF, there's no way that you can surpass the ADC noise limit.

Quote:

I calibrated the AS error signal into the displacement of the YARM cavity in the same way as I did before (elog).