40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Dec 14 01:42:53 2012, Den, Update, SUS, TT angle of incidence DSC_4791.jpeg
    Reply  Fri Dec 14 02:52:32 2012, Koji, Update, SUS, TT angle of incidence 
       Reply  Tue Dec 18 15:32:29 2012, Jenne, Update, SUS, TT angle of incidence 
    Reply  Fri Dec 14 03:15:49 2012, Jenne, Update, SUS, TT angle of incidence 
Message ID: 7826     Entry time: Fri Dec 14 01:42:53 2012     Reply to this: 7827   7828
Author: Den 
Type: Update 
Category: SUS 
Subject: TT angle of incidence 

I've estimated max possible angle of incidence on TT if we allow 20mm tolerance for the beam size and 5 mm tolerance for spot location on the mirror. It turns out to be

alpha = 43 degrees

So we need to cut the central part of the bracket. Then the max possible angle of incidence will be

alpha = 63 degrees

 

DSC_4791.jpeg

We can start the vent on Monday and use TT with an old bracket for yaw damping and later during the week we can install the brackets after they will be baked.