Message ID: 7806     Entry time: Mon Dec 10 22:34:34 2012     In reply to: 7804     Reply to this: 7820
Author: Den 
Type: Update 
Category: LSC 
Subject: beam inside DRMI is clipping on PR3 Tip-Tilt 

Quote:

 

That's OK, but its best to use standard notation. The power recycling gain is defined as the power incident on the BS divided by the power incident on the PRM from the laser side. You should also compare it with the PRC gain that you expect from mirror transmissions.

 I've made snapshots of PR2, PRM, ITMY and ITMX mirrors. Power buildup recycling gain (POWER BS / POWER PRM) was equal to 3-4.

PR2.bmp    PRM_LOCK.bmp    ITMY.png    ITMX.png