Sat Dec 8 04:12:38 2012, Den, Update, LSC, prcl
|
Sun Dec 9 01:21:51 2012, Den, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt 6x
|
Sun Dec 9 17:51:53 2012, rana, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt
|
Mon Dec 10 03:02:03 2012, Den, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt
|
Mon Dec 10 10:13:41 2012, Den, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt
|
Mon Dec 10 22:34:34 2012, Den, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt   
|
Thu Dec 13 03:20:48 2012, Den, Update, LSC, beam inside DRMI is clipping on PR3 Tip-Tilt  
|
|
Message ID: 7804
Entry time: Mon Dec 10 10:13:41 2012
In reply to: 7803
Reply to this: 7806
|
Author: |
Den |
Type: |
Update |
Category: |
LSC |
Subject: |
beam inside DRMI is clipping on PR3 Tip-Tilt |
|
|
That's OK, but its best to use standard notation. The power recycling gain is defined as the power incident on the BS divided by the power incident on the PRM from the laser side. You should also compare it with the PRC gain that you expect from mirror transmissions. |