Entry  Tue Dec 4 20:38:51 2012, jamie, Omnistructure, Computers, new (beta) version of nds2 installed on control room machines 
    Reply  Tue Dec 4 23:08:46 2012, Den, Omnistructure, Computers, new (beta) version of nds2 installed on control room machines 
       Reply  Wed Dec 5 09:42:46 2012, rana, Omnistructure, Computers, new (beta) version of NDS2 installed on control room machines 
          Reply  Wed Dec 5 16:54:29 2012, jamie, Omnistructure, Computers, new (beta) version of NDS2 installed on control room machines 
             Reply  Mon Dec 10 16:28:13 2012, jamie, Omnistructure, Computers, progressive retrieval of online data now possible with the new NDS2 client 
Message ID: 7793     Entry time: Wed Dec 5 16:54:29 2012     In reply to: 7791     Reply to this: 7805
Author: jamie 
Type: Omnistructure 
Category: Computers 
Subject: new (beta) version of NDS2 installed on control room machines 

Quote:

NDS2 is not designed for non DQ channels - it gets data from the frames, not through NDS1.

For getting the non-DQ stuff, I would just continue using our NDS1 compatible NDS mex files (this is what is used in mDV).

The NDS2 protocol is not for non-DQ, but the NDS2 client is capable of talking both the NDS1 and NDS2 protocols.

fb:8088 is an NDS1 server, so the client is talking NDS1 to fb.  It should therefore be capable of getting online data.

It doesn't seem to be seeing the online channels, though, so I'll work with Leo to figure out what's going on there.

The old mex functions, which like I said are now available, aren't capable of getting online data.