Message ID: 7707     Entry time: Tue Nov 13 21:05:22 2012
Author: Ayaka 
Type: Update 
Category: WienerFiltering 
Subject: Acoustic noise cancellation with MC 

 In order to perform acoustic noise cancellation with MCL signal, I am trying to find sweet spots for microphones.

I set microphones at various places around MC chambers, and see how coherent microphones and MC signals are.
I had checked the half part of MC.

  • data set #1
    place where I set the microphones (left), MCL signal (blue) and its error (green) (right top), and coherence between microphones (original: fine lines, error: thick lines) (right bottom).
    microphone_pos1.pdfpsd_coh1.png
  • data set #2
    microphone_pos2.pdfpsd_coh.png 
  •  data set #3
    microphone_pos3.pdfpsd_coh.png
  • data set #4
    microphone_pos4.pdfpsd_coh4.png

The acoustic noise around the MC2 chamber is most critical so far. I could subtract the signal and the sensitivity got 2 times better.
I will see the acoustic coupling from the other side of MC.