Message ID: 7702     Entry time: Tue Nov 13 00:28:10 2012
Author: Ayaka 
Type: Update 
Category: IOO 
Subject: MC locked, spots centered 

[Rana, Ayaka, Jenne]

We aligned the REFL beam to the center of PD.
Also we removed the small black parts from mirror holder so that the beam is not clipped. They are originally for holding the mirror, but the mirror should be held by the small screw on the side of the mirror mount. This screw was hidden by the label, so we moved the label on the right hand side of the mirror mount (See a picture below).  
DSC_4902.JPG

Also we removed the half-wave plates and PBS so that laser power is increased.
DSC_4904.JPG

Then I aligned the beam for PMC, locked MC, and centered the beam spots.

 spot1112.png

The MC2 pitch is a little bit high but still close enough to the center.

Jenne had also centered the beam spots on QPDs for WFS.