Thu Nov 1 17:37:00 2012, Steve, Update, General, bronze bushing for 40m vac
|
Fri Nov 2 03:28:54 2012, rana, Update, General, bronze bushing for 40m vac
|
Fri Nov 2 14:37:36 2012, Jenne, Update, General, Open-sided mount - why
|
Fri Nov 2 16:09:14 2012, Steve, Update, General, Open-sided mount - why
|
|
Message ID: 7662
Entry time: Fri Nov 2 14:37:36 2012
In reply to: 7660
Reply to this: 7663
|
Author: |
Jenne |
Type: |
Update |
Category: |
General |
Subject: |
Open-sided mount - why |
|
|
Quote: |
Quote: |
Suprema- SS clear edge mirror mount 2" diameter is modified for 40m vacuum use. One left and one right handed one. It's adjustment screw housing is bronze! It is not ideal for out gassing.
It will be baked and scanned. If it passes we should use it.
We may need these to bring out some pick-off beams.
|
I vote against it. We don't know about the grease inside the screw bushings - scans are not everything if adjusting the screw loosens up the grease. If we need more pick off mirrors lets just make some of the kind that we already use inside for the 2" optics.
|
I think Steve had these prepared in response to my question a few days ago of how badly do we need adjustability for the POX/POY mirrors? We already have cleaned open-sided mounts that have no adjustment screws. So as long as the beam reflects off the ITMs horizontally (which it should), we can do yaw adjustment by twisting the whole mount. We don't need super fine yaw adjustment, we just need to get the beam out, so this is probably good enough.
We should put the POY mirror on this open-sided mount (the one without screws) some time. Perhaps even today. |