Entry  Thu Oct 25 15:38:06 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
    Reply  Wed Oct 31 12:58:17 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror Transmission-plot@1064nm.pdfTransmission-data@1064nm.pdf
       Reply  Wed Oct 31 17:33:39 2012, Koji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
          Reply  Thu Nov 1 10:13:53 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
             Reply  Thu Nov 1 10:19:11 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
Message ID: 7654     Entry time: Thu Nov 1 10:19:11 2012     In reply to: 7653
Author: jamie 
Type: Update 
Category: Alignment 
Subject: Transmitance Measurements on LaserOptik mirror 

Quote:

Quote:

...Looks like the coating is out of spec at any angle for 1064nm. E11200219-v2

The coating should have very low 1064nm p transmission at 45 degrees, which the plot seems to indicate that it does.  That's really the only part of the spec that this measurement is saying anything about.    What makes you say it's out of spec?

Ok, yes, sorry, the data itself does indicate that the transmission is way too high at 45 degrees for 1064 p.