40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Oct 25 15:38:06 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
    Reply  Wed Oct 31 12:58:17 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror Transmission-plot@1064nm.pdfTransmission-data@1064nm.pdf
       Reply  Wed Oct 31 17:33:39 2012, Koji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
          Reply  Thu Nov 1 10:13:53 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
             Reply  Thu Nov 1 10:19:11 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
Message ID: 7653     Entry time: Thu Nov 1 10:13:53 2012     In reply to: 7648     Reply to this: 7654
Author: jamie 
Type: Update 
Category: Alignment 
Subject: Transmitance Measurements on LaserOptik mirror 

Quote:

...Looks like the coating is out of spec at any angle for 1064nm. E11200219-v2

The coating should have very low 1064nm p transmission at 45 degrees, which the plot seems to indicate that it does.  That's really the only part of the spec that this measurement is saying anything about.    What makes you say it's out of spec?

ELOG V3.1.3-