40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Oct 25 15:38:06 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Wed Oct 31 12:58:17 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
|
Wed Oct 31 17:33:39 2012, Koji, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Thu Nov 1 10:13:53 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Thu Nov 1 10:19:11 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
|
Message ID: 7644
Entry time: Wed Oct 31 12:58:17 2012
In reply to: 7624
Reply to this: 7648
|
Author: |
Raji |
Type: |
Update |
Category: |
Alignment |
Subject: |
Transmitance Measurements on LaserOptik mirror |
|
|
Quote: |
I measured the transmitted power @1064nm on one of the LaserOptik mirrors labled SN6
Here is the data
Polarization |
Input Angle |
Input Power(mW) |
Output Power(mW) |
Transmittance (%) |
p |
0 |
6.2 |
2.67 |
48 |
p |
0 |
100 |
52 |
52 |
p |
45 |
6.2 |
0.76 |
12 |
p |
45 |
100 |
1,5 |
1 |
s |
0 |
8.2 |
3.15 |
38 |
s |
0 |
100 |
40 |
0.4 |
s |
45 |
8.2 |
0.5 |
6 |
s |
45 |
100 |
0.66 |
0.006 |
The mirror is not a good reflector at 0 deg.
|
More data on the transmission. Measured the tranmission as a funtion of incidence angle at 1064nm |
|
|
|
|