Thu Oct 25 22:52:07 2012, janosch, Update, General, tip-tilt phase maps 6x
|
Thu Oct 25 23:00:44 2012, Manasa, Update, General, tip-tilt phase maps
|
Thu Oct 25 23:14:42 2012, janosch, Update, General, tip-tilt phase maps
|
Mon Oct 29 11:27:42 2012, Manasa, Update, General, tip-tilt phase maps 6x
|
Mon Oct 29 14:57:41 2012, janosch, Update, General, tip-tilt phase maps
|
|
Message ID: 7638
Entry time: Mon Oct 29 11:27:42 2012
In reply to: 7629
Reply to this: 7639
|
Author: |
Manasa |
Type: |
Update |
Category: |
General |
Subject: |
tip-tilt phase maps |
|
|
[Jan, Manasa]
Below are phasemaps for the tip-tilts with both tilt and RoC removed. We have not used Koji's code; but tweaked the earlier code to remove curvature.
The RoC values matched approximately to that quoted by Gari Lynn ~700m.
RoC of tip-tilts
Mirror
|
RoC (m) |
SN1 |
748.7176 |
SN2 |
692.7408 |
SN3 |
707.0336 |
SN4 |
625.5152 |
SN5 |
672.5340 |
SN6 |
663.7791 |
Phasemaps
The color scale for height are not the same for all mirrors.
SN1, SN2 and SN3
  
SN4, SN5 and SN6
  
|