Thu Oct 25 15:38:06 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Wed Oct 31 12:58:17 2012, Raji, Update, Alignment, Transmitance Measurements on LaserOptik mirror 
|
Wed Oct 31 17:33:39 2012, Koji, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Thu Nov 1 10:13:53 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
Thu Nov 1 10:19:11 2012, jamie, Update, Alignment, Transmitance Measurements on LaserOptik mirror
|
|
Message ID: 7624
Entry time: Thu Oct 25 15:38:06 2012
Reply to this: 7644
|
Author: |
Raji |
Type: |
Update |
Category: |
Alignment |
Subject: |
Transmitance Measurements on LaserOptik mirror |
|
|
I measured the transmitted power @1064nm on one of the LaserOptik mirrors labled SN6
Here is the data
Polarization |
Input Angle |
Input Power(mW) |
Output Power(mW) |
Transmittance (%) |
p |
0 |
6.2 |
2.67 |
48 |
p |
0 |
100 |
52 |
52 |
p |
45 |
6.2 |
0.76 |
12 |
p |
45 |
100 |
1,5 |
1 |
s |
0 |
8.2 |
3.15 |
38 |
s |
0 |
100 |
40 |
0.4 |
s |
45 |
8.2 |
0.5 |
6 |
s |
45 |
100 |
0.66 |
0.006 |
The mirror is not a good reflector at 0 deg. |