Wed Oct 24 14:15:34 2012, Ayaka, Update, Adaptive Filtering, microphone noise 
|
Wed Oct 24 15:29:52 2012, rana, Update, Adaptive Filtering, microphone noise
|
Wed Oct 24 17:02:01 2012, Jenne, Update, Adaptive Filtering, microphone noise
|
Wed Oct 24 22:20:24 2012, Den, Update, Adaptive Filtering, microphone noise
|
Thu Oct 25 09:53:23 2012, Ayaka, Update, Adaptive Filtering, microphone noise
|
Thu Oct 25 10:03:38 2012, rana, Update, Adaptive Filtering, microphone noise
|
Thu Oct 25 14:39:14 2012, Den, Update, Adaptive Filtering, microphone noise
|
|
Message ID: 7614
Entry time: Wed Oct 24 22:20:24 2012
In reply to: 7609
Reply to this: 7621
7622
|
Author: |
Den |
Type: |
Update |
Category: |
Adaptive Filtering |
Subject: |
microphone noise |
|
|
Quote: |
We have to change the sample rate and AA filter for the mic channels before going too far with the circuit design.
|
PEM model is running at 64K now. It turned out to be tricky to increase the rate:
- BLRMS are computationally expensive and original pem model did not start at any frequency higher then 16k ( at 16k cpu meter readings were 59/60 ). Also when we go higher then 16k, front-end gives the model less resources. I guess it is assumed that this model is iop and won't need too much time. So in the end I had to delete BLRMS blocks for all channels except for GUR2Z and MIC1.
- Foton files are modified during model compilation: lines with sampling rate and declaration of filters in the beginning of the file are changed only. Sos-representation and commands are the same. I hoped that filter commands will let me change sos-representation quickly. I've opened Foton and saved the file. However, Foton modified commands in such a way that the ratio of poles and zeros to sampling rate is preserved. I guess all filters have to be replaced or this process should be done in another way.
- BLRMS block uses low-pass filters below 0.01 Hz, increasing the sampling rate by a factor of 32 might make calculations incorrect. I'll check it.
We should also increase cut off frequency of the low-pass filter in the microphone pre-amplifier from 2 kHz up to ~20-30 kHz. |
|
|