Raji took the optics over. They were all measured at 0 deg incidence angle, although we will use them at the angles required for the recycling folding mirrors. Here's the summary from GariLynn:
In general all six pieces have a radius of curvature of around -700 meters.
They all fall off rapidly past 40 mm diameter. Within the 40 mm diameter the rms is ~10 nm for most. I can get finer analysis if you have something specific that you want to know.
All data are saved in Wyko format at the following location:
Gari
|
After a long search, I've found a way to finally read and analyze(?) the Wyko opd format data using Image SXM, an image analysis software working only on mac osx.