Not logged in |
 |
|
Wed Oct 10 20:27:40 2012, Den, Update, IOO, MCL, WFS triggers 
|
Thu Oct 18 03:45:56 2012, Jenne, Update, IOO, MCL, WFS triggers
|
Thu Oct 18 12:02:32 2012, Den, Update, IOO, MCL, WFS triggers
|
Fri Oct 19 01:11:18 2012, Jenne, Update, IOO, MCL, WFS triggers
|
|
Message ID: 7522
Entry time: Wed Oct 10 20:27:40 2012
Reply to this: 7572
|
Author: |
Den |
Type: |
Update |
Category: |
IOO |
Subject: |
MCL, WFS triggers |
|
|
I've added MCL and WFS stop triggers into C1MCS/SUS model. Threshold value of MC_TRANS can be changed in the text entry located in MC2_POSITION medm screen. I tried 2 cases: trigger either blocks signal before MCL filter bank input or after output. Due to filter history in the 1 case MC2 was still slightly disturbed (C1:SUS-MC2_ULPD_VAR ~= 15) right after unlock. In the second case there was no disturbance as we zero output signal, but then I had to add "clear history" command to the mcup script.
WFS triggers block the signal before ASCPIT/YAW filter bank.

|
|
|