40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Oct 10 20:27:40 2012, Den, Update, IOO, MCL, WFS triggers MC2_POS.pngmcl.pdf
    Reply  Thu Oct 18 03:45:56 2012, Jenne, Update, IOO, MCL, WFS triggers 
       Reply  Thu Oct 18 12:02:32 2012, Den, Update, IOO, MCL, WFS triggers 
          Reply  Fri Oct 19 01:11:18 2012, Jenne, Update, IOO, MCL, WFS triggers 
Message ID: 7522     Entry time: Wed Oct 10 20:27:40 2012     Reply to this: 7572
Author: Den 
Type: Update 
Category: IOO 
Subject: MCL, WFS triggers 

I've added MCL and WFS stop triggers into C1MCS/SUS model. Threshold value of MC_TRANS can be changed in the text entry located in MC2_POSITION medm screen. I tried 2 cases: trigger either blocks signal before MCL filter bank input or after output. Due to filter history in the 1 case MC2 was still slightly disturbed (C1:SUS-MC2_ULPD_VAR ~= 15) right after unlock. In the second case there was no disturbance as we zero output signal, but then I had to add "clear history" command to the mcup script.

WFS triggers block the signal before ASCPIT/YAW filter bank.

MC2_POS.png

Attachment 2: mcl.pdf  31 kB  Uploaded Wed Oct 10 21:29:44 2012  | Hide | Hide all
mcl.pdf
ELOG V3.1.3-