Sun Oct 7 23:39:10 2012, Den, Update, Modern Control, state estimation 
|
Mon Oct 8 09:51:30 2012, rana, Update, Modern Control, state estimation
|
Mon Oct 8 12:34:52 2012, Den, Update, Modern Control, state estimation
|
|
Message ID: 7499
Entry time: Mon Oct 8 09:51:30 2012
In reply to: 7497
Reply to this: 7503
|
Author: |
rana |
Type: |
Update |
Category: |
Modern Control |
Subject: |
state estimation |
|
|
I guess that the estimated state has the same low pass filter, effectively, that we use to low pass the feedback signal in SUSPOS. I wonder if there is an advantage to the state estimation or not. Doesn't the algorithm also need to know about the expected seismic noise transmission from the ground to the optic? |