40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sun Oct 7 23:39:10 2012, Den, Update, Modern Control, state estimation est_time.pngest_freq.pdf
    Reply  Mon Oct 8 09:51:30 2012, rana, Update, Modern Control, state estimation 
       Reply  Mon Oct 8 12:34:52 2012, Den, Update, Modern Control, state estimation 
Message ID: 7499     Entry time: Mon Oct 8 09:51:30 2012     In reply to: 7497     Reply to this: 7503
Author: rana 
Type: Update 
Category: Modern Control 
Subject: state estimation 

 

 I guess that the estimated state has the same low pass filter, effectively, that we use to low pass the feedback signal in SUSPOS. I wonder if there is an advantage to the state estimation or not. Doesn't the algorithm also need to know about the expected seismic noise transmission from the ground to the optic?