40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Sep 26 17:09:15 2012, Den, Update, SUS, TT 
    Reply  Thu Sep 27 15:21:04 2012, Steve, Update, SUS, TT height adaptor & PTICH damping 09271201.PDFIMG_1656.JPGIMG_1654.JPG
       Reply  Fri Oct 12 10:39:45 2012, Steve, Update, SUS, TT PITCH damping IMG_1709.JPG
          Reply  Fri Oct 12 14:01:33 2012, Koji, Update, SUS, TT PITCH damping 
             Reply  Fri Oct 12 16:59:26 2012, steve, Update, SUS, TT PITCH damping 
       Reply  Wed Oct 17 08:30:49 2012, Steve, Update, SUS, PTICH damping needed 
          Reply  Wed Oct 17 11:15:05 2012, Den, Update, SUS, PITCH damping needed pitch_damping.png
             Reply  Thu Oct 18 02:42:38 2012, Den, Update, SUS, PITCH damping needed 7x
                Reply  Fri Oct 19 18:30:07 2012, Den, Update, SUS, PITCH damping needed damp.pngpitch.png
                   Reply  Sat Oct 20 01:23:56 2012, Den, Update, SUS, PITCH damping needed P1010059.jpgP1010058.jpgP1010060.jpg
                      Reply  Sat Oct 20 20:37:55 2012, Den, Update, SUS, PITCH damping needed DSC_4778.JPGpitch.JPGyaw.JPGDSC_4776.JPG
                      Reply  Mon Oct 22 11:26:12 2012, rana, Update, SUS, PITCH damping needed 
                         Reply  Tue Oct 23 01:46:53 2012, Den, Update, SUS, PITCH damping needed Mirror_Holder_ECD_NEW_DRAWING.PDFTT_DAMPING_DRAWING.PDF
                            Reply  Tue Oct 23 17:12:30 2012, Den, Update, SUS, PITCH damping needed simple_drawing.PDF
                               Reply  Wed Oct 24 01:02:10 2012, Koji, Update, SUS, PITCH damping needed 
                                  Reply  Mon Oct 29 18:14:55 2012, Den, Update, SUS, PITCH damping needed DSC_4787.JPGDSC_4791.JPG
                            Reply  Tue Oct 23 18:18:29 2012, Jenne, Update, SUS, PITCH damping needed 
Message ID: 7446     Entry time: Thu Sep 27 15:21:04 2012     In reply to: 7443     Reply to this: 7535   7566
Author: Steve 
Type: Update 
Category: SUS 
Subject: TT height adaptor & PTICH damping 

Quote:

  [Koji, Steve, Den]

TT alignment is fine, yaw damping is satisfactory, pitch damping is slow. We might want to add magnets to the mirror and attach blades to the frame for pitch edge current damping.

We are moving towards electronics testing.

Atm1,  TT 1.5" high adaptor base will be back from the shop in 10 days.

Atm2,  There is no PITCH damping, YAW edie current damping works well at 0.5 mm gap

Atm3,  Adjustable Al -disc that contains a small magnet is purely designed.

We have to come up with a solution to have damping in PITCH

Attachment 1: 09271201.PDF  725 kB  | Hide | Hide all
09271201.PDF
Attachment 2: IMG_1656.JPG  1.733 MB  | Hide | Hide all
IMG_1656.JPG
Attachment 3: IMG_1654.JPG  1.740 MB  | Hide | Hide all
IMG_1654.JPG
ELOG V3.1.3-