Subject: Last of In-vac mirror photos taken 

Quote:

[Manasa, Jenne]

We took the last of the in-vac photos of mirrors today.  I'll post in the morning.

Tomorrow, I'll align the DRMI once more to check, and get IPPOS and IPANG out of the vacuum.  I'll  take a look at POX, POY and POP, but we may just have to cross our fingers and hope for the best on those ones.  They were pretty hard to get out of the vac during their initial alignment, since they're so weak.

Also, tomorrow morning Steve is going to try out our new light access connector!!!!  I'm so excited!

The goal is to put heavy doors on, on Wed, and start pumping Wed afternoon / Thurs evening.

 The photos on the OMC table are particularly tricky, since the camera plus the 'bathroom' mirror add a lot of weight....even if the MC locked, the input beam would be completely different, so all of the beams would be wrong.

During some of the work on the BS table, ITMY was realigned to have its beam retro-reflect, since the weight of the camera plus mirror was shifting all of the suspended optics on the BS table.  ITMY was restored after that, for subsequent photos.