Message ID: 7400     Entry time: Mon Sep 17 23:58:01 2012     In reply to: 7399     Reply to this: 7420
Author: rana 
Type: Update 
Category: General 
Subject: Last of In-vac mirror photos taken 

 My hope is that the DRMI flashes will be bright enough to see on the PO beams. IF we get 10 mW through the Faraday, you should get some buildup when the carrier resonates in the DRMI.

If the recycling gain is 10 and the pickoff fraction is 100 ppm you ought to get ~10 uW on PO. How much of the recycling cavity power gets out of POP?