[Rana, Jenne]
We aligned the DRMI, and have concluded that it looks good enough that we should close up and pump down soon. We still need to use the camera to check things, and get all pickoff beams out of the chambers, so don't get too excited yet.
We looked at the mode matching telescope's calculated beam propagation, and since we're using spherical telescope mirrors at non-zero degree incidence angle, we expect an astigmatism about like what we are seeing on the AS camera. This matches up with the measurements that Mike posted from his and Q's measurements earlier today. We think that it has 'always' been this way, and someone just picked a camera position such that the beam used to look more round than it does now.
We aren't entirely sure what's up with the SRM - it almost looks like the pitch and yaw are coupled, but it was pretty easy to align the PRMI. We don't see any evidence of the crazy, crappy beam that we did before the vent. This means we have fixed most of the bad clipping problems we were seeing over the last ~year.
In the process of aligning the DRMI, we fixed up the input beam alignment - we were not hitting the exact centers of the MMT mirrors (in pitch, mostly), so we fixed that, and propagated the alignment fix through the chain. In all, we touched the knobs on PZT1, MMT1, MMT2, PZT2. The beam then went through the SRM, and we touched a few of the output steering mirrors to get the beam centered on all mirrors.
I remeasured the MC spot positions, and they're a little worse than they have been. Some of the spots seem to be off by 1.75mm (or less) on MC 1 and 3. The numbers, MC1,2,3 pitch, then MC1,2,3 yaw are: 1.749759 9.744013 1.025681 -0.791683 -1.338786 -1.779958
A question to consider before doing the final-final alignment checking is: do we need to get the MC spots centered better than this, especially in light of the potential PMC axis having moved? |