Author: janosch, Steve 
Type: Update 
Category:  
Subject: ETMX, scattering preps 

The alignment of the pick-off mirror near ETMX is done. Everything turned out to be easy once we realized that there is no sense getting the alignment laser (going through viewport to pick-off to ITMX) back to ETMX. It is only necessary to hit ITMX somehow, since this makes sure that there is one scattered beam that will make it from ITMX to pick-off through viewport.

After the auxiliary optic (that we never used in the end) was removed again, we levelled the optical table.

So in the current setup, we can have small-angle scattering measurements on ITMX and large-angle scattering measurements on ETMX.

Attachment 1: IMG_1609.JPG  2.055 MB  Uploaded Fri Aug 31 11:36:06 2012  | Show | Hide all | Show all
Attachment 2: IMG_1608b.jpg  2.073 MB  Uploaded Tue Sep 4 18:27:21 2012  | Hide | Hide all | Show all
IMG_1608b.jpg
ELOG V3.1.3-