40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Aug 24 22:01:15 2012, Jenne, Update, IOO, MC spot position - close MCdecenter_24Aug2012.png
    Reply  Sun Aug 26 12:26:44 2012, Jenne, Update, IOO, MC spot position - not done yet 
       Reply  Mon Aug 27 01:05:36 2012, Jenne, Update, IOO, MC spot position - callin' it quits MCdecenter_26Aug2012.png
          Reply  Mon Aug 27 12:03:54 2012, Koji, Update, IOO, MC spot position - callin' it quits 
             Reply  Mon Aug 27 18:32:48 2012, Jenne, Update, IOO, MC spot position - Jenne is stupid 
                Reply  Mon Aug 27 18:59:24 2012, jamie, Update, IOO, MC ASC screen was confusing - Jenne is not stupid Screenshot-1.pngScreenshot-2.png
                   Reply  Mon Aug 27 23:52:59 2012, Jenne, Update, IOO, MC Spots centered MCdecenter_26Aug2012.png
Message ID: 7280     Entry time: Mon Aug 27 01:05:36 2012     In reply to: 7277     Reply to this: 7284
Author: Jenne 
Type: Update 
Category: IOO 
Subject: MC spot position - callin' it quits 
spot positions in mm (MC1,2,3 pit MC1,2,3 yaw):
[-0.98675603448324423, -0.94064212026141558, 2.6749179375892544, -0.65896393156684185, -0.4508281650731974, -0.55109088188064204]

MC3 pitch isn't what I'd like it to be, but MC1 and MC3 pitch aren't quite acting in relation to each other how I'd expect. Sometimes they move in common, sometimes differentially, which is confusing since I have only ever been touching (on the PSL table) the last steering mirror before the beam is launched into the vacuum.

The latest few measurements have all been with the WFS off, but reflection of ~0.48 . I haven't figured out why yet, but MC1 and MC3 yaw WFS outputs start to escalate shortly after the WFS becoming engaged, and they keep knocking the MC out of lock, so I'm leaving them off for now, to be investigated in the morning.