It seems as though there is something funny going on around ~1.5 Hz, starting a little over an hour ago.
We see it in the BLRMS channels, the raw seismometer time series, as well as in various suspensions and LSC control signals. It's also pretty easy to see on the camera views of all the spots (MC, arms, transmissions....AS is a little harder to tell since it's flashing, but it's there too).
The plots I'm attaching are only for ~10min after the jump happened, but there has been no change in the BLRMS since it started. Usually, we'd see an earthquake in all the channels, and even big ones ring down after a little while. This is concentrated at a pretty narrow frequency (some of Den's plots for later have this peak), and it's not ringing down, so it's not clear what is going on.
Here is a whole pile of plots. Recall that the T-240 is plugged into the "STS_3" channels, and we don't have BLRMS for it, so you can look at the time series, but not any frequency specific stuff.
|