Wed Aug 8 19:54:06 2012, Manasa, Configuration, IOO, MC trans optics configured
|
Wed Aug 8 22:12:30 2012, rana, Configuration, IOO, MC trans optics configured
|
Wed Aug 8 22:17:43 2012, Manasa, Configuration, IOO, MC trans optics configured
|
Fri Aug 10 09:54:51 2012, Manasa, Configuration, IOO, MC trans optics configured
|
Fri Aug 10 11:05:33 2012, jamie, Configuration, IOO, MC trans optics configured
|
Fri Aug 10 15:05:52 2012, Manasa, Configuration, IOO, MC trans optics configured
|
Thu Aug 16 17:28:51 2012, Manasa, Configuration, IOO, MC trans optics configured
|
Tue Oct 2 14:20:33 2012, Manasa, Configuration, IOO, PDA255 not working
|
|
Message ID: 7206
Entry time: Thu Aug 16 17:28:51 2012
In reply to: 7144
Reply to this: 7462
|
Author: |
Manasa |
Type: |
Configuration |
Category: |
IOO |
Subject: |
MC trans optics configured |
|
|
Quote: |
Quote: |
Quote: |
Quote: |
Quote: |
The PDA255 is a good ringdown detector - Steve can find one in the 40m if you ask him nicely.
|
We found a PDA255 but it doesn't seem to work. I am not sure if that is one you are mentioning...but I'll ask Steve tomorrow!
|
I double checked the PDA255 found at the 40m and it is broken/bad. Also there was no success hunting PDs at Bridge. So the MC trans is still in the same configuration. Nothing has changed. I'll try doing ringdown measurements with PDA400 today.
|
Can you explain more what "broken/bad" means? Is there no signal? Is it noisy? Glitch? etc.
|
The PD saturates the oscilloscope just by switching on the power; with no real signal at all. But Steve helped locating a PD that is not being used at the AP table. So I will check it and replace the current one if it works!
|
Koji opened up the PD and found that the screw connecting the PD to the pole was doing an additional job as well; connecting the power cable to the PD output in the inside. The PD is now fixed! Yippie...we have two PDA255 s at 40m now!! |