Entry  Tue Aug 14 22:16:46 2012, Jenne, Update, LSC, LSC whitening triggers 
    Reply  Wed Aug 15 09:09:45 2012, jamie, Update, LSC, LSC whitening triggers 
Message ID: 7184     Entry time: Tue Aug 14 22:16:46 2012     Reply to this: 7188
Author: Jenne 
Type: Update 
Category: LSC 
Subject: LSC whitening triggers 

I'm ~30% of the way through implementing LSC whitening filter triggers.  I think that everything I have done should be compile-able, but please don't compile c1lsc tonight.  I haven't tested it, and some channel names have changed, so I need to fix the LSC screen when I'm not falling asleep.

Also, Rana pointed out that we may not want the whitening to trigger on immediately upon acquiring lock - if there are other modes ringing down in the cavity, or some weird transients, we don't want to amplify those signals.  We want to wait a second or so for them to die down, then turn on analog whitening.  Jamie - do you know how long the "unit delay" delays things in the RCG?  Do those do what I naively think they do?  I'll ask you in the morning.