Entry  Tue Aug 14 11:33:14 2012, Jamie Alex Den, Update, CDS, AI and AA filters ai.png
    Reply  Tue Aug 14 11:46:22 2012, Jamie, Update, CDS, IPC senders know nothing about rates of IPC receivers, we need to filter signals appropriately 
       Reply  Tue Aug 14 13:21:34 2012, Jenne, Update, CDS, IPC senders no nothing about rates of IPC receivers, we need to filter signals appropriately 
Message ID: 7177     Entry time: Tue Aug 14 13:21:34 2012     In reply to: 7175
Author: Jenne 
Type: Update 
Category: CDS 
Subject: IPC senders no nothing about rates of IPC receivers, we need to filter signals appropriately 

Quote:

Quote:

When signals are transmitted between the models running at different rates, no AI or AA filters are automatically applied. We need to fix our models.

This is known, but we just haven't fully groked it yet.  We need to look closely at every place we have IPCs between models running at different rates.  The sender has no information about receivers, so it can't reasonably do anything to pre-filter the signal on it's own.

So for transmission from:

  • faster -> slower models: add anti-aliasing on the sender side
  • slower -> faster models: add anti-imaging on the receiver side

 *sigh* This is one of those things that I meant to take care of months ago, but haven't yet.  I agree that it needs doing.  It's been on my whiteboard to-do list for a long time now.  Bad Jenne for not taking care of it.