40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Aug 10 09:47:19 2012, Masha, Update, Computers, FE Status 
    Reply  Fri Aug 10 11:08:26 2012, jamie, Update, Computers, FE Status 
Message ID: 7143     Entry time: Fri Aug 10 11:08:26 2012     In reply to: 7138
Author: jamie 
Type: Update 
Category: Computers 
Subject: FE Status 

Quote:

The c1lsc and c1sus screens are red in the front-end status. I restarted the frame builder, and hit the "global diag reset" button, but to no avail. Yesterday, the only thing Den and I did to c1sus was install a new c1pem model. I got rid of the changes and switched to the old one (I ran rtcds build, install, restart), but the status is still the same.

 The issue you're seeing here is stalled mx_stream processes on the front ends.  On the troublesome front ends you can log in and restart the mx_streams with the "mxstreamrestart" command.

ELOG V3.1.3-