40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 7074     Entry time: Wed Aug 1 22:37:21 2012
Author: Jenne 
Type: Update 
Category: ASS 
Subject: Filters installed in the ASS 

As part of trying to figure out what is going on with the ASS, I wanted to figure out what filters are installed on which lockins.

Each "DoF"(1-6) has a zpk(0.1,0.0001,1)gain(1000), which is a lowpass with 60dB of gain at DC, and unity gain at high frequencies.

For the lockins, since there are so many, I made a spreadsheet to keep track of them (attached). 

So, what's the point?  The point is, I think that all of the LOCKIN_I filter modules should be the same, with a single low pass filter.  The Q filter banks don't matter, since we don't use those signals, and the signals are grounded inside the model.  The phase of each lockin was / should be tuned such that all of the interesting signal goes to I, and nothing goes to Q.  The SIG filter modules seem okay, in that they're all the same, except for their band pass frequency.  I just need to check to see what frequency the ASS scripts are trying to actuate at, to make sure we're bandpassing the correct things.

 

Attachment 1: ASS_lockin_filters_1Aug2012.pdf  40 kB  | Hide | Hide all
ASS_lockin_filters_1Aug2012.pdf ASS_lockin_filters_1Aug2012.pdf
ELOG V3.1.3-