40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jul 30 09:00:18 2012, steve, Update, PSL, PMC is still not fixed pmcA.pngpmcB.png
    Reply  Mon Jul 30 10:05:29 2012, Jenne, Update, PSL, PMC is still not fixed 
Message ID: 7048     Entry time: Mon Jul 30 10:05:29 2012     In reply to: 7047
Author: Jenne 
Type: Update 
Category: PSL 
Subject: PMC is still not fixed 

Quote:

The PMC was locking right the way, but it's transmission would not go up.  Finally I get it back up by moving the "sticky" DC Gain slider up and down a few times.

 The FSS was -2.9, and the PMC won't lock happily unless you bring this back to 0.  The symptom that this is happening is that the PMC reflection camera is totally saturated, but the PMC still looks like it's locked on 00.

ELOG V3.1.3-