40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Thu Jul 26 17:39:49 2012, Den, Update, digital noise, biquad key is working   
|
Thu Jul 26 21:31:44 2012, Den, Update, digital noise, online biquad works 
|
Fri Jul 27 14:30:49 2012, Jamie, Update, digital noise, biquad key is working
|
Mon Jul 30 14:24:25 2012, Den, Update, digital noise, biquad key is working
|
|
Message ID: 7045
Entry time: Fri Jul 27 14:30:49 2012
In reply to: 7041
Reply to this: 7050
|
Author: |
Jamie |
Type: |
Update |
Category: |
digital noise |
Subject: |
biquad key is working |
|
|
What is "DQF"? Is that the biquad? And what is the difference between DF1 and DF2? Why don't you just write out the name, so it's more clear. |