40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 11 22:51:11 2012, Jenne, Update, Computers, tdsavg not working 
    Reply  Mon Jun 25 11:23:14 2012, Jenne, Update, Computers, tdsavg not working 
Message ID: 6866     Entry time: Mon Jun 25 11:23:14 2012     In reply to: 6795
Author: Jenne 
Type: Update 
Category: Computers 
Subject: tdsavg not working 

Quote:

LSCoffsets script, and any others depending on tdsavg will not work until this is fixed.

 LSCoffsets is working again. 

tdsavg (now, but didn't used to) needs "LIGONDSIP=fb" to be specified.  Jamie just put this in the global environment, so tdsavg should just work like normal again.

Also, the rest of the LSCoffsets script (really the subcommand offset2) was tsch syntax, so I created offset3 which is bash syntax.

Now we can use LSCoffsets again.

ELOG V3.1.3-